Orifice & Venturi Flow Meter Calculator - Flow Rate from Differential Pressure (ISO 5167)

A pressure gauge reads a few kPa across a plate in your pipe — and from that single number you can know exactly how much fluid is flowing. That's the elegant principle behind orifice plates and venturi meters, the two most common differential-pressure flow meters in industry. Squeeze the flow through a constriction, measure the pressure drop, and Bernoulli's principle gives you the flow rate. This free Orifice & Venturi Flow Meter Calculator applies the ISO 5167 equations to turn your differential-pressure reading into volumetric and mass flow — or reverse-solve the bore size you need — for both liquids and gases.

Orifice Meter working calculator
Figure 1 Orifice Venturi meter

The Flow Meter Calculator

Choose orifice or venturi, then solve for flow rate from your differential pressure, or reverse-solve the bore diameter for a target flow. The tool returns volumetric flow, mass flow, velocity, beta ratio and the velocity-of-approach factor. Consistent SI units.

 Orifice & Venturi Flow Meter Calculator

Flow rate from differential pressure · ISO 5167 · liquids & gases
Find flow rate
Find bore size (reverse)
Device & fluid
Geometry & differential pressure
Target flow & conditions
result
mass flow (kg/s)
bore velocity (m/s)
beta ratio β
vel. approach E
Q = C · E · ε · (π/4)d² · √(2ΔP/ρ), with E = 1/√(1−β⁴), β = d/D. Mass flow qₘ = Q·ρ. Orifice C ≈ 0.60–0.61; classical venturi C = 0.984 (cast) to 0.995 (machined). For gases set ε < 1 and keep ΔP/P₁ ≤ 0.25. Keep β between 0.2 and 0.75 for a valid ISO 5167 measurement.
Validation note: the calculator follows the ISO 5167 differential-pressure equation. For water through an orifice with D = 100 mm, d = 50 mm (β = 0.5), ΔP = 20 kPa, C = 0.61, it gives Q ≈ 0.0078 m³/s (28.2 m³/hr) with velocity-of-approach factor E = 1.0328. The same geometry as a machined venturi (C = 0.995) passes about 46 m³/hr — more flow for the same ΔP thanks to its higher, more efficient discharge coefficient.

How Differential-Pressure Flow Meters Work

Orifice plates and venturi meters share one principle. When fluid is forced through a constriction, it speeds up — and by conservation of energy (Bernoulli), its pressure drops. The faster the flow, the bigger the pressure drop. So by measuring the differential pressure ΔP = P1 − P2 across the constriction, we can back-calculate the flow rate.

The key insight: the pressure drop is proportional to the square of the flow rate. So flow rate is proportional to √ΔP — which is why every DP flow equation has a square root in it, and why these meters lose sensitivity at low flows.

The ISO 5167 Flow Equation

The international standard ISO 5167 governs these meters. Its volumetric flow equation is:

Q = C · E · ε · (π/4) d² · √(2ΔP / ρ)

where C is the discharge coefficient, E the velocity-of-approach factor, ε the expansibility factor (1 for liquids), d the bore/throat diameter, ΔP the differential pressure, and ρ the density. Mass flow follows immediately:

qₘ = Q · ρ

The square-root dependence on ΔP and the density term connect directly to the physics in our pressure drop & head loss calculator — the same Bernoulli energy balance underlies both.

Beta Ratio & Velocity of Approach

The beta ratio is the heart of the geometry:

β = d / D

Because the upstream pipe area is finite, the incoming fluid already has some velocity — corrected by the velocity-of-approach factor:

E = 1 / √(1 − β⁴)
Beta βE factorBehaviour
0.21.001Large ΔP signal, high permanent loss
0.51.033Balanced — common choice
0.71.147Low loss, weaker signal
0.751.210ISO 5167 upper limit
Stay in range: ISO 5167 is valid for β between 0.2 and 0.75. Lower β gives a stronger, more accurate signal but wastes more pressure; higher β saves pressure but weakens the reading. The calculator flags values outside this band.

The Discharge Coefficient

Real flow isn't ideal — the stream contracts (the vena contracta), and friction bites. The discharge coefficient C corrects for all of this:

DeviceDischarge coefficient C
Orifice plate (sharp-edged)~0.60 – 0.61
Venturi, cast convergent0.984
Venturi, machined convergent0.995
Flow nozzle~0.95 – 0.99

For orifices, C varies slightly with beta and Reynolds number via the precise Reader-Harris/Gallagher equation, but ~0.61 is an excellent working value. The venturi's high, stable C is its big advantage. The flow regime (via the Reynolds number) determines whether your C is in its valid range.

Orifice vs Venturi: Which to Use?

FeatureOrifice PlateVenturi Tube
CostLow — cheap plateHigh — precision casting
Permanent pressure lossHigh (~50–75% of ΔP)Low (~10–20%)
Discharge coefficient~0.61 (lower)~0.98–0.99 (higher, stable)
Size / spaceCompact (thin plate)Large & long
Installation / serviceEasy to inspect & replacePermanent, bulky
Best forGeneral, dirty fluids, tight budgetsLarge pipes, energy-sensitive, clean fluids
The trade-off in one line: the orifice is cheap but wastes pumping energy; the venturi is expensive but recovers most of the pressure. Over years of operation on a big pipe, the venturi's lower loss can pay for itself in pump-energy savings — a genuine pump power consideration.

Liquids vs Gases: The Expansibility Factor

For liquids (incompressible), density is constant and the expansibility factor is exactly ε = 1 — the basic equation applies directly.

For gases, the pressure drop makes the gas expand and its density fall across the constriction. The expansibility factor ε < 1 corrects for this. For a venturi (ISO 5167-4):

ε = 1 − (0.649 + 0.696β⁴) · ΔP / (κ P₁)

where κ is the isentropic exponent (1.40 for air) and P1 the absolute upstream pressure. In practice ε is usually 0.98–1.00.

The #1 gas error: using standard-condition density instead of density at operating pressure and temperature. Always use ρ = PM/(ZRT) at flowing conditions. Also keep ΔP / P1 ≤ 0.25 to keep ε accurate.

Worked Example

Water through an orifice plate: pipe D = 100 mm, bore d = 50 mm, ΔP = 20 kPa, ρ = 1000 kg/m³, C = 0.61:

  • β = 50/100 = 0.5
  • E = 1/√(1 − 0.5⁴) = 1/√0.9375 = 1.0328
  • Bore area = (π/4)(0.05)² = 0.001963 m²
  • Q = 0.61 × 1.0328 × 1 × 0.001963 × √(2×20000/1000)
  • Q = 0.61 × 1.0328 × 0.001963 × 6.325 ≈ 0.0078 m³/s = 28.2 m³/hr
  • Mass flow = 0.0078 × 1000 ≈ 7.8 kg/s

Swap to a machined venturi (C = 0.995) and the same ΔP yields ~46 m³/hr — the venturi's efficiency in action.

Common Mistakes

  • Standard-condition gas density. Always use density at operating P and T — the biggest gas error.
  • Forgetting the velocity-of-approach factor E. At high β it's a significant correction, not optional.
  • Wrong discharge coefficient. ~0.61 for orifice, ~0.98–0.99 for venturi — don't mix them up.
  • Beta ratio out of range. Keep 0.2 ≤ β ≤ 0.75 for a valid ISO 5167 measurement.
  • Skipping expansibility for gases. Liquids ε = 1, but gases need ε < 1.
  • Ignoring installation requirements. You need 10–40 pipe diameters of straight run upstream for a good profile.
  • Confusing ΔP with permanent loss. The measured ΔP is not the permanent pressure loss — some recovers downstream.

Frequently Asked Questions

How do you calculate flow rate from differential pressure?

Use Q = C·E·ε·(π/4)d²·√(2ΔP/ρ), where E = 1/√(1−β⁴) and β = d/D. Multiply by density for mass flow. Liquids use ε = 1.

What is the difference between an orifice and a venturi meter?

Both use a constriction and DP, but an orifice is a cheap thin plate with high permanent loss and C ≈ 0.61, while a venturi is a smooth, costlier tube with low permanent loss and C ≈ 0.98–0.99.

What is the beta ratio?

β = d/D, the bore-to-pipe diameter ratio. ISO 5167 requires 0.2–0.75. Lower β gives a stronger signal but more pressure loss.

What is the discharge coefficient?

C corrects ideal flow for contraction and friction. Orifice ~0.60–0.61 (Reader-Harris/Gallagher); venturi ~0.984 (cast) to 0.995 (machined).

Does the calculator work for gases?

Yes — set the expansibility ε < 1, use operating-condition density, and keep ΔP/P₁ ≤ 0.25. Liquids use ε = 1.

Why is a venturi better than an orifice plate?

Its gradual diverging section recovers most of the pressure, so permanent loss is far lower — more energy-efficient, though costlier and bulkier than an orifice.

Conclusion

Orifice and venturi meters turn a simple pressure reading into a precise flow measurement using one elegant equation: Q = C·E·ε·(π/4)d²·√(2ΔP/ρ). Get the beta ratio, discharge coefficient and (for gases) expansibility right, keep β in the ISO 5167 range, and use density at operating conditions — and you can measure flow reliably with nothing more than a differential-pressure gauge.

Use the calculator above to convert your ΔP reading to flow rate, or to size the bore for a target flow, in either device — backed by the same ISO 5167 method used across industry.


For more fluid mechanics, pipe-flow and CFD tutorials plus free engineering calculators, explore Free CFD Tutorial. If this tool helped you, please share it with your fellow engineers and students.